Tests as per IEC 60384-14 (2nd Edition 1993 +A1 1995) and EN132400 (1994 +A2 1998 +A3 1998) or class X & Y interference suppression capacitors
Standard Tests - EMI Suppressors
PEAK PULSE TEST
Typical waveform. The exact values of T1 & T2 depend on the capacitance value being tested.
Class
Peak impulse voltage three times before endurance test
X1
4kV
X2
2,5kV
Y1
8kV
Y2
5kV
ENDURANCE TEST
The capacitors are tested for 1.000 hours at upper category temperature
with a voltage of 1,25 x UR for class X and 1,7 xUR for class Y.
Every hour the test voltage is increased up to 1000VRMS/50Hz for a period of 0,1 s.
ACTIVE FLAMMABILITY TEST
The capacitors are tested at the rated voltage (Vac) at 50Hz with superimposed 20 pulses of voltage according to its class with an interval between the successive pulses of 5s.
The rated voltage is maintained for 2 min after the last discharge. The cheese-cloth
around the capacitor shall not burn with a flame.
Class
Peak discharge voltage
X1
4kV
X2, Y3, Y4
2.5kV
Y2
5kV
CHARGE AND DISCHARGE TEST
The capacitors are subject to 10.000 cycles of charge and discharge at the rate of approximately one operation per second and the maximum rate of change of voltage (dV/dt) shall be aproximately
100 V/micro-second.
EMI Suppression Capacitors:
EMI suppression capacitors - X2 class - MKP41
EMI suppression capacitors - X1 class - MKP51
EMI suppression capacitors - Y2 class - MKP31
EMI suppression capacitors - X2 +2Y2 delta by-pass filter- ISF 103
EMI suppression capacitors - X2 RC filter - MKP44
Standard Tests - EMI Suppressors
Characteristics - EMI Suppressors (X2 & X1)
©
2005 Unicomp 21,
S.L.
|
Tel.
:+34 91 801 25 51 - Fax:+34 91 801 25 49 -
info@unicomp21.com